Digital mammograms may present an overexposed area in the peripheral part of the breast, which is visually shown as a darker area with lower contrast. This has a direct impact on image quality and affects image visualisation and assessment. This paper presents an automatic method to enhance the overexposed peripheral breast area providing a more homogeneous and improved view of the whole mammogram. The method automatically restores the overexposed area by equalising the image using information from the intensity of non-overexposed neighbour pixels. The correction is based on a multiplicative model and on the computation of the distance map from the breast boundary. A total of 334 digital mammograms were used for evaluation. Mammograms before and after enhancement were evaluated by an expert using visual comparison. In 90.42% of the cases, the enhancement obtained improved visualisation compared to the original image in terms of contrast and detail. Moreover, results show that lesions found in the peripheral area after enhancement presented a more homogeneous intensity distribution. Hence, peripheral enhancement is shown to improve visualisation and will play a role in further development of CAD systems in mammography
dc.description.sponsorship
This work was partially funded by the Spanish R+D+I Grant no. TIN2012-37171-C02-01. M. Tortajada holds a UdG BR-GR10 grant
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier
dc.relation
info:eu-repo/grantAgreement/MINECO//TIN2012-37171-C02-01/ES/IA-BIOBREAST: ANALISIS TEMPORAL Y DETECCION AUTOMATICA DE LESIONES EN IMAGENES MULTIMODALES./
dc.relation.isformatof
Reproducció digital del document publicat a: http://dx.doi.org/10.1016/j.compbiomed.2014.03.010
dc.relation.ispartof
© Computers in Biology and Medicine, 2014, vol. 50, p. 32-40
dc.relation.ispartofseries
Articles publicats (D-ATC)
dc.rights
Tots els drets reservats
dc.subject
dc.title
Breast peripheral area correction in digital mammograms
dc.type
info:eu-repo/semantics/article
dc.rights.accessRights
info:eu-repo/semantics/embargoedAccess
dc.embargo.terms
Cap
dc.date.embargoEndDate
info:eu-repo/date/embargoEnd/2026-01-01
dc.type.version
info:eu-repo/semantics/publishedVersion
dc.identifier.doi
dc.identifier.idgrec
022081
dc.contributor.funder
dc.relation.ProjectAcronym