Confinement of FRP concrete columns: Review of design guidelines and comparison with experimental results
dc.contributor.author
dc.date.accessioned
2022-10-20T11:31:20Z
dc.date.available
2022-10-20T11:31:20Z
dc.date.issued
2022-03-01
dc.identifier.issn
0465-2746
dc.identifier.uri
dc.description.abstract
A regulatory framework is required to ensure the correct design of Fibre-Reinforced Polymers (FRPs) increasingly being used as an externally-bonded strengthening system on concrete columns. Several design guidelines on the confinement of FRP concrete have been developed over the past few years worldwide, each proposing a different approach, resulting in different predictions. This study aims to evaluate and compare nine international design guidelines used to predict the compressive strength of confined concrete in FRP-strengthened concrete columns and weigh them against experimental results. The results of this investigation reveal that the predictions from the guidelines on the compressive strengthening of FRP-confined concrete are generally suitable for circular columns, with the ACI-440 and CNR-DT 200 guideline predictions being two of the most accurate. Nevertheless, the guidelines generally tend to overestimate the load-carrying capacity for the compressive strength of FRP-confined concrete in non-circular columns, for which further experimental work using large-scale specimens is required
Confinamiento de columnas de hormigón con FRP: revisión de normativas y sus predicciones. El crecimiento en el uso de polímeros reforzados con fibra (FRP) como sistema de refuerzo externo en columnas de hormigón requiere de un marco regulatorio para su correcto diseño. En los últimos años se han desarrollado diferentes guías y normativas de diseño, teniendo cada una de ellas un planteamiento diferente y, por lo tanto, arrojando resultados dispares. Esta investigación pretende contrastar con resultados experimentales las predicciones que nueve normativas internacionales hacen sobre la resistencia a compresión de una columna de hormigón confinada con FRP. Los resultados de la investigación muestran que las estimaciones de las normativas sobre la resistencia de las columnas de hormigón confinadas con FRP son, en general, adecuadas para columnas circulares; destacan como las más precisas la ACI-440 y la CNR-DT 200. Por contra, en el caso de columnas no circulares los resultados obtenidos tienden a sobreestimar la resistencia a compresión de las columnas confinadas con FRP, en este caso sería necesario continuar investigando en modelos a gran escala
dc.description.sponsorship
The authors are grateful for the support of the Spanish Government (MCIN), Project Ref. PID2020-119015GB-C22.The authors would also like to thank the Engi-neering School of La Almunia (University of Zara-goza) and the AMADE research group (University of Girona)
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
Editorial CSIC
dc.relation
PID2020-119015GB-C22
dc.relation.isformatof
Reproducció digital del document publicat a: https://doi.org/10.3989/mc.2022.03821
dc.relation.ispartof
Materiales de Construccion, 2022, vol. 72, núm. 345, p. e274
dc.relation.ispartofseries
Articles publicats (D-EMCI)
dc.rights
Attribution 4.0 International
dc.rights.uri
dc.subject
dc.title
Confinement of FRP concrete columns: Review of design guidelines and comparison with experimental results
dc.type
info:eu-repo/semantics/article
dc.rights.accessRights
info:eu-repo/semantics/openAccess
dc.relation.projectID
info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2020-119015GB-C22/ES/MEJORA DE LA EFICIENCIA DEL REFUERZO DE ESTRUCTURAS DE HORMIGON CON FRP. ANALISIS Y DISEÑO DE SISTEMAS DE ANCLAJE PARA EVITAR EL FALLO PREMATURO POR ADHERENCIA/
dc.type.version
info:eu-repo/semantics/publishedVersion
dc.identifier.doi
dc.identifier.idgrec
034979
dc.contributor.funder
dc.type.peerreviewed
peer-reviewed
dc.relation.FundingProgramme
dc.relation.ProjectAcronym
dc.identifier.eissn
1988-3226