Electrical Generation of a Ground-Level Solar Thermoelectric Generator: Experimental Tests and One-Year Cycle Simulation
dc.contributor.author
dc.date.accessioned
2020-07-06T10:37:44Z
dc.date.available
2020-07-06T10:37:44Z
dc.date.issued
2020-07-02
dc.identifier.uri
dc.description.abstract
Solar thermoelectric generators (STEGs) are a promising technology to harvest energy for off-grid applications. A wide variety of STEG designs have been proposed with the aim of providing non-intermittent electrical generation. Here, we designed and tested a STEG 0.5 m long formed by nine commercial thermoelectric generator modules and located at ground level. Data were used to validate a numerical model that was employed to simulate a one-year cycle. Results confirmed the very high variability of energy generation during daylight time due to weather conditions. By contrast, energy generation during night was almost independent of atmospheric conditions. Annual variations of nighttime energy generation followed the trend of the daily averaged soil temperature at the bottom of the device. Nighttime electrical energy generation was 5.4 times smaller than the diurnal one in yearly averaged values. Mean energy generation values per day were 587 J d−1 (daylight time) and 110 J d−1 (nighttime). Total annual energy generation was 255 kJ. Mean electrical output power values during daylight and nighttime were 13.4 mW and 2.5 mW, respectively. Annual mean output power was 7.9 mW with a peak value of 79.8 mW
dc.description.sponsorship
This work was partially funded by the University of Girona under grant MPCUdG2016-4
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
MDPI (Multidisciplinary Digital Publishing Institute)
dc.relation.isformatof
Reproducció digital del document publicat a: https://doi.org/10.3390/en13133407
dc.relation.ispartof
Energies, 2020, vol. 13, núm. 13, p. 3407
dc.relation.ispartofseries
Articles publicats (D-EMCI)
dc.rights
Attribution 4.0 International
dc.rights.uri
dc.subject
dc.title
Electrical Generation of a Ground-Level Solar Thermoelectric Generator: Experimental Tests and One-Year Cycle Simulation
dc.type
info:eu-repo/semantics/article
dc.rights.accessRights
info:eu-repo/semantics/openAccess
dc.type.version
info:eu-repo/semantics/publishedVersion
dc.identifier.doi
dc.identifier.idgrec
031683
dc.type.peerreviewed
peer-reviewed
dc.identifier.eissn
1996-1073