When filling the form you are requesting a copy of the article, that is deposited in the institutional repository (DUGiDocs), at the autor or main autor of the article. It will be the same author who decides to give a copy of the document to the person who requests it, if it considers it appropriate. In any case, the UdG Library doesn’t take part in this process because it is not authorized to provide restricted articles.
Share
The sequential application of a polymer inclusion membrane (PIM), composed of poly(vinylidenefluoride-co-hexafluoropropylene) and the anionic extractant Aliquat 336, and a microporous polytetrafluoroethylene (PTFE) gas-permeable membrane was utilized for the first time to develop a flow analysis (FA) system, for the automatic determination of trace levels of arsenate (As(V)) in drinking water as arsine. The system incorporated a flow-through extraction cell for separation and preconcentration of arsenate and a gas-diffusion cell for the separation of arsine prior to its spectrophotometric determination based on the discoloration of a potassium permanganate solution. Under optimal conditions the FA system is characterized by a limit of detection of 3.0 μg L −1 As(V) and repeatability of 1.8% (n = 5, 25 μg L −1 As(V)) and 2.8% (n = 5, 50 μg L −1 As(V)). The newly developed FA method was successfully applied to the determination of arsenate in drinking water samples in the μg L −1 concentration range ​