Robust Fault Detection System for Insulin Pump Therapy Using Continuous Glucose Monitoring
dc.contributor.author
dc.date.accessioned
2025-01-16T18:05:14Z
dc.date.available
2025-01-16T18:05:14Z
dc.date.issued
2012-09-05
dc.identifier.issn
1932-2968
dc.identifier.uri
dc.description.abstract
The popularity of continuous subcutaneous insulin infusion (CSII), or insulin pump therapy, as a way to deliver insulin more physiologically and achieve better glycemic control in diabetes patients has increased. Despite the substantiated therapeutic advantages of using CSII, its use has also been associated with an increased risk of technical malfunctioning of the device, which leads to an increased risk of acute metabolic complications, such as diabetic ketoacidosis. Current insulin pumps already incorporate systems to detect some types of faults, such as obstructions in the infusion set, but are not able to detect other types of fault such as the disconnection or leakage of the infusion set
dc.description.sponsorship
This work has been funded by the Wellcome Trust, the Spanish Ministry of Science and Innovation through grant DPI2010-20764-C02, the European Union through FEDER funds and Generalitat de Catalunya under grant 2009 SGR 523
dc.format.extent
11 p.
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
Diabetes Technology Society
dc.relation
DPI2010-20764-C02-02
dc.relation.isformatof
Versió postprint del document publicat a: https://doi.org/10.1177/193229681200600518
dc.relation.ispartof
© Journal of Diabetes Science and Technology, 2012, vol. 6, núm. 5, p. 1131-1141
dc.relation.ispartofseries
Articles publicats (D-EEEiA)
dc.rights
Tots els drets reservats
dc.source
Herrero i Viñas, Pau Calm i Puig, Remei Vehí, Josep Armengol Llobet, Joaquim Georgiou, Pantelis Oliver, Nick Toumazou, Christofer 2012 Robust Fault Detection System for Insulin Pump Therapy Using Continuous Glucose Monitoring Journal of Diabetes Science and Technology 6 5 1131 1141
dc.subject
dc.title
Robust Fault Detection System for Insulin Pump Therapy Using Continuous Glucose Monitoring
dc.type
info:eu-repo/semantics/article
dc.rights.accessRights
info:eu-repo/semantics/openAccess
dc.relation.projectID
info:eu-repo/grantAgreement/MICINN//DPI2010-20764-C02-02/ES/NUEVAS ESTRATEGIAS DE CONTROL GLUCEMICO POSTPRANDIAL MEDIANTE TERAPIA CON BOMBA DE INSULINA EN DIABETES TIPO 1/
dc.type.version
info:eu-repo/semantics/acceptedVersion
dc.identifier.doi
dc.identifier.idgrec
017319
dc.contributor.funder
dc.type.peerreviewed
peer-reviewed
dc.relation.FundingProgramme
dc.relation.ProjectAcronym
dc.identifier.PMID
23063040
dc.identifier.PMCID
PMC3570848