Sorbent-packed needle microextraction trap for benzene, toluene, ethylbenzene, and xylenes determination in aqueous samples
dc.contributor.author
dc.date.accessioned
2025-01-16T11:59:44Z
dc.date.available
2025-01-16T11:59:44Z
dc.date.issued
2010-09
dc.identifier.issn
1615-9306
dc.identifier.uri
dc.description.abstract
A needle trap (NT) device filled with Carbopack X as a sorbent material is evaluated for the static headspace analysis of benzene, toluene, ethylbenzene, and xylene (BTEX) compounds in aqueous samples. Injection parameters used with the NT device (e.g. volume of carrier gas and time to open the split valve) are evaluated to determine the mechanism involved during the desorption and transferring of the target compounds into the GC column. Furthermore, different parameters affecting the adsorption capacity of the sorbent are studied (e.g. sampling time and temperature, headspace/sample volume ratio, salting-out, and stirring). The evaluation of the method with aqueous samples shows that repeatability and recoveries with the NT device are equivalent to those obtained using solid-phase microextraction with a carboxen/PDMS (CAR/PDMS) coating. LODs obtained with flame ionization detection are in the range of 10-25 μg/L, and in the range of hundredths of μg/L with MS detection. The method developed is satisfactorily applied to the analysis of aqueous samples obtained from wastewater treatment plants
dc.description.sponsorship
Research funding: MICINN. Grant Number: CTM2008-06847-C02-02/TECNO and Spanish Ministry of Education (FPU). Grant Number: AP2008-01628
dc.format.extent
8 p.
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
Wiley-VCH Verlag
dc.relation
info:eu-repo/grantAgreement/MICINN//CTM2008-06847-C02-02/ES/EVALUACION DE LA EFICACIA DE LAS PLANTAS DE TRATAMIENTO DE AGUAS RESIDUALES EN LA ELIMINACION DE COMPUESTOS ORGANICOS EMERGENTES DE LAS AGUAS PARA SU REUTILIZACION/
dc.relation.isformatof
Versió postprint del document publicat a: https://doi.org/10.1002/jssc.201000213
dc.relation.ispartof
© Journal of Separation Science, 2010, vol. 33, núm. 17-18, p. 2833-2840
dc.relation.ispartofseries
Articles publicats (D-Q)
dc.rights
Tots els drets reservats
dc.source
De Crom, Jorn Claeys, Sara Godayol Boix, Anna Alonso Roura, Mònica Anticó i Daró, Ma. Enriqueta Sánchez Navarro, Juan Manuel 2010 Sorbent-packed needle microextraction trap for benzene, toluene, ethylbenzene, and xylenes determination in aqueous samples Journal of Separation Science 33 17-18 2833 2840
dc.subject
dc.title
Sorbent-packed needle microextraction trap for benzene, toluene, ethylbenzene, and xylenes determination in aqueous samples
dc.type
info:eu-repo/semantics/article
dc.rights.accessRights
info:eu-repo/semantics/openAccess
dc.relation.projectID
EVALUACION DE LA EFICACIA DE LAS PLANTAS DE TRATAMIENTO DE AGUAS RESIDUALES EN LA ELIMINACION DE COMPUESTOS ORGANICOS EMERGENTES DE LAS AGUAS PARA SU REUTILIZACION
dc.type.version
info:eu-repo/semantics/acceptedVersion
dc.identifier.doi
dc.identifier.idgrec
012845
dc.contributor.funder
dc.type.peerreviewed
peer reviewed
dc.identifier.eissn
1615-9314
dc.identifier.PMID
20730828