Arresting propagating kinkbands: failure mechanisms under longitudinal compression of carbon-boron fibre hybrids
Compartir
The use of Fibre Reinforced Polymers (FRPs) in structural applications has been steadily growing,
thanks to the continuous improvements in their performance and to the ever-increasing understanding
of their mechanical behaviour. However, one long-standing weakness of these materials, still limiting
their potential, is their performance under longitudinal compression. This is due to compressive failure
being most often caused by a material instability phenomenon leading to kinkband formation and
propagation, causing compressive strength to be typically much lower than the tensile one [1]. Among
FRPs, boron-fibre composites have unmatched compressive strength. Typically, due to high
production cost of boron fibre, these composites are used in high-performance specialty applications.
Nonetheless, advanced design strategies optimizing material adoption, like the use of fibre-hybrid
composites and material-by-design approaches (which are gaining more and more traction in the field
[2]), could pave the way to a more widespread adoption. Carbon/boron fibre hybrids are reported to
have exceptional compressive performances [3], but, as of today, the literature on the subject is scarce.
An in-depth understanding of the mechanisms governing failure under compression of these materials
will clarify the motives of their strength; furthermore, it will lay the grounds for the development of
the next generation of composite materials and structures, surpassing current limitations.
In view of this, we present a detailed experimental study on the failure mechanisms of carbon/boron
fibre hybrid under compression. We used IM7/8552 prepreg from Hexcel and HyBor 52 from
Specialty Materials Inc. HyBor 52 is a second-generation carbon/boron fibre hybrid prepreg; it has a
boron content of 52 fibres-per-inch, while the resin material and the carbon fibre used in it are Toray
TG275-1E (double cure epoxy, allowing wide cure cycle compatibility with other epoxies) and
T1100G, respectively. We designed cross-ply hybrid small-scale notched specimens having the
carbon/boron fibre-hybrid material, HyBor 52, in the 0° plies. We then tested under compression the
specimens using a Deben micromechanical testing device; specifically, we performed in-situ Scanning
Electron Microscope (SEM) tests, to directly observe failure mechanisms under load, and in-situ
optical microscope tests with speckled specimens for subsequent Digital Image Correlation (DIC)
analysis.
The results of one sample test are illustrated in Fig. 1, which reports the load displacement plot of one
of the tests we performed, along with SEM pictures taken at different load levels. A kinkband is seen
to develop from the notch tip and to reach the first boron fibre on its path; there, the kinkband is
arrested, while the test continues and the load increase steadily. After a subsequent load drop occurring
at a much higher load level, no further propagation of the initial kinkband is observed. Rather, multiple
disjointed kinkbands are observed in the carbon fibre regions of the composite at different locations,
while boron fibres remain mostly intact, justifying the still impressive load carrying capability of the
specimen.
The results of this study shed light on the reasons for the impressive performance of carbon-boron
fibre hybrid under longitudinal compression. Most importantly, they reveal, for the first time, the
possibility of arresting propagating kinkbands in Carbon FRPs, in this case thanks to the adoption of
boron fibres, that act as arresters and promote damage diffusion. They also provide important hints on how future composite materials with improved longitudinal compressive performance could be
obtained
Tots els drets reservats