Actualment les necessitats energètiques estan canviant d’una manera molt ràpida ja que
aquestes necessitats cada cop son mes grans. Els consums elèctrics de la societat estan
augmentant i tenim la necessitat de poder reduir-los. Amb la situació del canvi climàtic i les
emissions generades per els éssers humans fa que els consums elevats de recursos estiguin
poc justificats, i per tant s’ha de resoldre aquesta situació.
La gran majoria d’edificis públics varen ser construïts en unes èpoques en les que les
exigències energètiques no eren tant elevades i per tant estaven ben projectats, però en la
actualitat, els consums d’aquests son massa elevats i s’han de reduir al màxim. Actualment
tenim suficient tecnologia com per a poder reduir els consums energètics sense la necessitat
de perdre els beneficis obtinguts els últims anys.
L’edifici ha estat estructurat separant les diferents plantes que té, que son la planta baixa,
primera i segona planta, i soterrani. La planta baixa és la zona més transitada i utilitzada de
tot l’edifici ja que hi tenim totes les aules on s’executen la gran majoria de classes relacionades
amb les enginyeries de l’àmbit industrial. La primera i segona planta, son utilitzades per
professorat de algunes especialitats com poden ser la física o la mecànica. Pel que fa el
soterrani, hi ha una sèrie de laboratoris i aules que s’utilitzen sobretot per als grups de recerca
de l’àmbit de la enginyeria.
L’abast del projecte serà la substitució de les actuals lluminàries per altres de característiques
similars però amb la tecnologia LED, i el control de tot el sistema d’il·luminació per mitjà del
sistema KNX. Tota aquesta gestió es dura a terme en les zones més freqüentades com son
els passadissos, les aules, els lavabos i els laboratoris. Els despatxos dels professors i les
aules dels grups de recerca s’ha desestimat la opció de modificar-ho ja que el cost de fer-ho i
la reducció energètica que hagués suposat feia inviable la seva execució
Currently, energy needs are changing very quickly because
these needs are getting bigger every time. Society's electricity consumption is
increasing and we need to be able to reduce them. With the climate change situation and the
emissions generated by human beings causes the high consumption of resources
hardly justified, and therefore this situation must be resolved.
The vast majority of public buildings were built in periods in which
energy demands were not so high and therefore they were well projected, but in the
currently, the consumption of these is too high and must be reduced as much as possible. currently
we have enough technology to be able to reduce energy consumption without the need
of losing the profits obtained in recent years.
The building has been structured by separating the different floors it has, which are the ground floor,
first and second floor, and basement. The ground floor is the busiest and most used area of
the whole building since we have all the classrooms where the vast majority of related classes take place
with industrial engineering. The first and second floor are used by
teachers of some specialties such as physics or mechanics. As for the
basement, there are a series of laboratories and classrooms that are mainly used for research groups
from the field of engineering.
The scope of the project will be the replacement of the current luminaires with others of similar characteristics
similar but with LED technology, and the control of the entire lighting system through the
KNX system. All this management is carried out in the most frequented areas such as sleep
corridors, classrooms, toilets and laboratories. The offices of the teachers and the
classrooms of the research groups, the option to modify it has been rejected since the cost of doing so i
the energy reduction that would have made its execution unfeasible
dc.format.mimetype
application/pdf
dc.language.iso
cat
dc.relation.ispartofseries
Enginyeria Elèctrica (TFG)
dc.rights
Attribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.uri
dc.subject
dc.title
Millora de l’eficiència energètica de l’enllumenat del P2 de la EPS - UdG
dc.type
info:eu-repo/semantics/bachelorThesis
dc.rights.accessRights
info:eu-repo/semantics/openAccess
dc.audience.educationlevel
Estudis de grau
dc.coverage.geolocation
east=2.8294466; north=41.9639914; name=Escola Politècnica Superior - EPS (UdG)
Localització