Advanced control system for reverse osmosis optimization in water reuse systems
dc.contributor.author
dc.date.accessioned
2022-01-24T12:11:37Z
dc.date.available
2022-01-24T12:11:37Z
dc.date.issued
2021-12-15
dc.identifier.issn
0011-9164
dc.identifier.uri
dc.description.abstract
A main reverse osmosis (RO) limitation is the operational costs (including energy filtration costs), which are significantly affected by energy costs and the expense of membrane maintenance. Both costs are affected by influent characteristics, including feedwater temperatures (T), electrical conductivity (EC), and recovery set points. A fuzzy logic advanced control system optimizes the RO operational costs considering feedwater EC and T as input values, and the RO recovery setpoint as a control action. Verification results show that, once calibrated, the simulation of the control system can save more than one million euros per year in large RO facilities (>30.000m3·day-1). Which represents a reduction of 0.11€·m-3 of influent treated water
dc.description.sponsorship
The authors would like to acknowledge the support from the RegiReu project (COMRDI16-1-0062) from the Agency for Business Competitiveness (ACCIÓ). Albert Galizia would also like to thank the AGAUR for his predoctoral grant (2021 FI_B 00069). Hèctor Monclús gratefully acknowledges the Ramon y Cajal Research Fellowship (RYC2019-026434-I). LEQUIA and ICRA have been recognized as consolidated research groups by the Catalan Government; codes 2017-SGR-1552 and 2017-SGR-1318, respectively. Gaetan Blandin has received funding from the People Programme (Marie Curie Actions) of the Seventh Framework Programme of the European Union (FP7/2007-2013) under the REA grant agreement n°600388 (TECNIOspring programme), and from the Catalan Government's Agency for Business Competitiveness (ACCIO)
Open Access funding provided thanks to the CRUE-CSIC agreement with Elsevier
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier
dc.relation.isformatof
Reproducció digital del document publicat a: https://doi.org/10.1016/j.desal.2021.115284
dc.relation.ispartof
Desalination, 2021, vol. 518, art.núm.115284
dc.relation.ispartofseries
Articles publicats (D-EQATA)
dc.rights
Attribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.uri
dc.title
Advanced control system for reverse osmosis optimization in water reuse systems
dc.type
info:eu-repo/semantics/article
dc.rights.accessRights
info:eu-repo/semantics/openAccess
dc.type.version
info:eu-repo/semantics/publishedVersion
dc.identifier.doi
dc.identifier.idgrec
033817
dc.type.peerreviewed
peer-reviewed