The inadequate use of the determination coefficient in analytical calibrations: How other parameters can assess the goodness-of-fit more adequately
dc.contributor.author
dc.date.accessioned
2022-01-17T13:20:35Z
dc.date.available
2022-01-17T13:20:35Z
dc.date.issued
2021-12-01
dc.identifier.issn
1615-9306
dc.identifier.uri
dc.description.abstract
Simple linear regression using ordinary least-squares is the most common function applied in laboratories for analytical calibrations. The determination and/or the correlation coefficients are usually the parameters applied for assessing the goodness-of-fit of a simple linear calibration. However, these parameters are unable to detect the highly biased results at low calibration levels that are obtained with ordinary least-squares. In this study, the use of other parameters based on the relative standard errors of the calculated contents is evaluated. It has been found that these alternative parameters can detect the biased results obtained at low calibration levels with ordinary least-squares, being the relative standard error the one that seems to provide the most adequate results. Ordinary least-squares should only be applied if the lower limit of quantification is set to at least five times above the conventional limit of quantification. For trace analysis, where the lowest possible limit of quantification is required, weighted least-squares should be applied to obtain accurate estimates, especially at low concentrations. One of the greatest advantages of the relative standard error is that this parameter can be determined for all types of regression functions and is not limited to calibrations with linear relationships between the variables
dc.description.sponsorship
Open Access funding provided thanks to the CRUE-CSIC agreement with Wiley
dc.format.extent
11 p.
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
Wiley-VCH Verlag
dc.relation.isformatof
Reproducció digital del document publicat a: https://doi.org/10.1002/jssc.202100555
dc.relation.ispartof
Journal of Separation Science, 2021, vol. 44, núm. 24, p. 4431-4441
dc.relation.ispartofseries
Articles publicats (D-Q)
dc.rights
Reconeixement-NoComercial 4.0 Internacional
dc.rights.uri
dc.source
Sánchez Navarro, Juan Manuel 2021 The inadequate use of the determination coefficient in analytical calibrations: How other parameters can assess the goodness-of-fit more adequately Journal of Separation Science 44 24 4431 4441
dc.subject
dc.title
The inadequate use of the determination coefficient in analytical calibrations: How other parameters can assess the goodness-of-fit more adequately
dc.type
info:eu-repo/semantics/article
dc.rights.accessRights
info:eu-repo/semantics/openAccess
dc.type.version
info:eu-repo/semantics/publishedVersion
dc.identifier.doi
dc.identifier.idgrec
034430
dc.type.peerreviewed
peer-reviewed
dc.identifier.eissn
1615-9314