Sensitivity of the NEXT experiment to Xe-124 double electron capture

Martínez Lema, Gonzalo
Martínez-Vara, M.
Sorel, Michel
Adams, C.
Álvarez Puerta, Vicente
Arazi, L.
Arnquist, I.J.
Azevedo, C.D.R.
Bailey, K.
Benlloch Rodríguez, J.M.
Borges, Filipa I.G.M.
Byrnes, N.
Cárcel García, Sara
Carrión, J.V.
Cebrián, Susana
Church, E.
Conde, Carlos A.N.
Contreras, T.
Díaz López, G.
Díaz Medina, José
Diesburg, M.
Escada, J.
Esteve, Raúl
Felkai, R.
Fernandes, A.F.M.
Fernandes, L.M.P.
Ferrario, Paola
Ferreira, Antonio Luis
Freitas, Elisabete D.C.
Generowicz, J.
Ghosh, S.
Goldschmidt, Azriel
Gómez Cadenas, Juan José
González-Díaz, Diego
Guenette, R.
Gutiérrez, Rafael María
Haefner, J.
Hafidi, K.
Hauptman, John M.
Henriques, C.A.O.
Hernando Morata, J.A.
Herrero, Vicente
Ifergan, Y.
Johnston, S.
Jones, Benjamin J.P.
Kekic, M.
Labarga, Luis A.
Laing, Andrew
Lebrun, P.
López-March, N.
Losada, Marta
Mano, R.D.P.
Martín-Albo Simón, Justo
Martínez Pérez, Alberto
McDonald, Alison D.
Monrabal Capilla, Francesc
Monteiro, Cristina M.B.
Mora, Francisco José
Muñoz Vidal, J.
Novella, P.
Nygren, David R.
Palmeiro, B.
Para, A.
Pérez Pérez, Javier
Querol, M.
Redwine, A.B.
Renner, Joshua
Repond, J.
Riordan, S.
Rodríguez García, Y.
Rogers, L.
Romeo, B.
Romo-Luque, C.
Santos, Filomena P.
dos Santos, Joaquim M.F.
Simón Estévez, Ander
Sofka, C.
Stiegler, T.
Toledo, J.F.
Torrent Collell, Jordi
Usón, A.
Veloso, João F.C.A.
Webb, R.C.
Weiss-Babai, R.
White, James T.
Woodruff, K.
Yahlali Haddou, Nadia
Compartir
Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture (2νEC EC) has been predicted for a number of isotopes, but only observed in 78Kr, 130Ba and, recently, 124Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process, 0νEC EC. Here we report on the current sensitivity of the NEXT-White detector to 124Xe 2νEC EC and on the extrapolation to NEXT-100. Using simulated data for the 2νEC EC signal and real data from NEXT-White operated with 124Xe-depleted gas as background, we define an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of 124Xe and for a 5-year run, a sensitivity to the 2νEC EC half-life of 6 × 1022 y (at 90% confidence level) or better can be reached ​
Aquest document està subjecte a una llicència Creative Commons:Reconeixement (by) Creative Commons by4.0