Dynamic Rule-Based Algorithm to Tune Insulin-on-Board Constraints for a Hybrid Artificial Pancreas System
dc.contributor.author
dc.date.accessioned
2020-03-19T10:16:54Z
dc.date.available
2020-03-19T10:16:54Z
dc.date.issued
2020
dc.identifier.issn
2040-2295
dc.identifier.uri
dc.description.abstract
The artificial pancreas (AP) is a system intended to control blood glucose levels through automated insulin infusion, reducing the burden of subjects with type 1 diabetes to manage their condition. To increase patients’ safety, some systems limit the allowed amount of insulin active in the body, known as insulin-on-board (IOB). The safety auxiliary feedback element (SAFE) layer has been designed previously to avoid overreaction of the controller and thus avoiding hypoglycemia. In this work, a new method, so-called “dynamic rule-based algorithm,” is presented in order to adjust the limits of IOB in real time. The algorithm is an extension of a previously designed method which aimed to adjust the limits of IOB for a meal with 60 grams of carbohydrates (CHO). The proposed method is intended to be applied on hybrid AP systems during 24 h operation. It has been designed by combining two different strategies to set IOB limits for different situations: (1) fasting periods and (2) postprandial periods, regardless of the size of the meal. The UVa/Padova simulator is considered to assess the performance of the method, considering challenging scenarios. In silico results showed that the method is able to reduce the time spent in hypoglycemic range, improving patients’ safety, which reveals the feasibility of the approach to be included in different control algorithms
dc.description.sponsorship
This work has been partially funded by the Spanish Government (grant no. DPI2016-78831-C2-2-R), National Counsel of Technological and Scientific Development, CNPq-Brazil (grant nos. 207688/2014-1 and 202050/2015-7), and Formación de Professorado Universitario (grant no. FPU0244 2015)
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
Hindawi
dc.relation
DPI2016-78831-C2-2-R
dc.relation.isformatof
Reproducció digital del document publicat a: https://doi.org/10.1155/2020/1414597
dc.relation.ispartof
Journal of Healthcare Engineering, 2020, art. núm. 1414597
dc.relation.ispartofseries
Articles publicats (D-EEEiA)
dc.rights
Attribution 4.0 International
dc.rights.uri
dc.subject
dc.title
Dynamic Rule-Based Algorithm to Tune Insulin-on-Board Constraints for a Hybrid Artificial Pancreas System
dc.type
info:eu-repo/semantics/article
dc.rights.accessRights
info:eu-repo/semantics/openAccess
dc.relation.projectID
info:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2016-78831-C2-2-R/ES/Soluciones para la Mejora de la Eficiencia y Seguridad del Páncreas Artificial mediante Arquitecturas de Control Multivariable Tolerantes a Fallos/
dc.type.version
info:eu-repo/semantics/publishedVersion
dc.identifier.doi
dc.identifier.idgrec
029918
dc.contributor.funder
dc.type.peerreviewed
peer-reviewed
dc.relation.FundingProgramme
dc.relation.ProjectAcronym
dc.identifier.eissn
2040-2309