Accurate γ and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm
dc.contributor.author
dc.date.accessioned
2018-12-14T08:53:43Z
dc.date.available
2018-12-14T08:53:43Z
dc.date.issued
2015-12-21
dc.identifier.issn
0168-9002
dc.identifier.uri
dc.description.abstract
We report the performance of a 10 atm Xenon/trimethylamine time projection chamber (TPC) for the detection of X-rays (30 keV) and γ-rays (0.511-1.275 MeV) in conjunction with the accurate tracking of the associated electrons. When operated at such a high pressure and in ∼1%-admixtures, trimethylamine (TMA) endows Xenon with an extremely low electron diffusion (1.3±0.13mm-σ (longitudinal), 0.95±0.20mm-σ (transverse) along 1 m drift) besides forming a convenient 'Penning-Fluorescent' mixture. The TPC, that houses 1.1 kg of gas in its fiducial volume, operated continuously for 100 live-days in charge amplification mode. The readout was performed through the recently introduced microbulk Micromegas technology and the AFTER chip, providing a 3D voxelization of 8mm×8mm×1.2mm for approximately 10 cm/MeV-long electron tracks. Resolution in energy (ε) at full width half maximum (R) inside the fiducial volume ranged from R=14.6% (30 keV) to R=4.6%(1.275MeV). This work was developed as part of the R&D program of the NEXT collaboration for future detector upgrades in the search of the neutrino-less double beta decay (ββ0ν) in 136Xe, specifically those based on novel gas mixtures. Therefore we ultimately focus on the calorimetric and topological properties of the reconstructed MeV-electron tracks. In particular, the obtained energy resolution has been decomposed in its various contributions and improvements towards achieving the R=1.4%√1MeV/ε levels obtained in small sensors are discussed
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier
dc.relation.isformatof
Reproducció digital del document publicat a: https://doi.org/10.1016/j.nima.2015.08.033
dc.relation.ispartof
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2015, vol. 804, p. 8-24
dc.relation.ispartofseries
Articles publicats (D-EMCI)
dc.rights
Attribution 4.0 International
dc.rights.uri
dc.subject
dc.title
Accurate γ and MeV-electron track reconstruction with an ultra-low diffusion Xenon/TMA TPC at 10 atm
dc.type
info:eu-repo/semantics/article
dc.rights.accessRights
info:eu-repo/semantics/openAccess
dc.type.version
info:eu-repo/semantics/publishedVersion
dc.identifier.doi
dc.identifier.idgrec
024020
dc.type.peerreviewed
peer-reviewed