Unannounced Meals in the Artificial Pancreas: Detection Using Continuous Glucose Monitoring
dc.contributor.author
dc.date.accessioned
2018-03-20T15:50:07Z
dc.date.available
2018-03-20T15:50:07Z
dc.date.issued
2018-03-16
dc.identifier.uri
dc.description.abstract
The artificial pancreas (AP) system is designed to regulate blood glucose in subjects with type 1 diabetes using a continuous glucose monitor informed controller that adjusts insulin infusion via an insulin pump. However, current AP developments are mainly hybrid closed-loop systems that include feed-forward actions triggered by the announcement of meals or exercise. The first step to fully closing the loop in the AP requires removing meal announcement, which is currently the most effective way to alleviate postprandial hyperglycemia due to the delay in insulin action. Here, a novel approach to meal detection in the AP is presented using a sliding window and computing the normalized cross-covariance between measured glucose and the forward difference of a disturbance term, estimated from an augmented minimal model using an Unscented Kalman Filter. Three different tunings were applied to the same meal detection algorithm: (1) a high sensitivity tuning, (2) a trade-off tuning that has a high amount of meals detected and a low amount of false positives (FP), and (3) a low FP tuning. For the three tunings sensitivities 99 ± 2%, 93 ± 5%, and 47 ± 12% were achieved, respectively. A sensitivity analysis was also performed and found that higher carbohydrate quantities and faster rates of glucose appearance result in favorable meal detection outcomes
dc.description.sponsorship
This work was funded by the Spanish Government through grants DPI2016-78831-C2-1-R and DPI2016-78831-C2-2-R, the University of Girona through grant BR2014/51, and the European Union through Fondo Europeo de Desarrollo Regional (FEDER) Funds
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
MDPI (Multidisciplinary Digital Publishing Institute)
dc.relation
DPI2016-78831-C2-2-R
dc.relation.isformatof
Reproducció digital del document publicat a: https://doi.org/10.3390/s18030884
dc.relation.ispartof
Sensors, 2018, vol.18, núm. 3, p. 884
dc.relation.ispartofseries
Articles publicats (D-EEEiA)
dc.rights
Attribution 3.0 Spain
dc.rights.uri
dc.subject
dc.title
Unannounced Meals in the Artificial Pancreas: Detection Using Continuous Glucose Monitoring
dc.type
info:eu-repo/semantics/article
dc.rights.accessRights
info:eu-repo/semantics/openAccess
dc.relation.projectID
info:eu-repo/grantAgreement/MINECO/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2016-78831-C2-2-R/ES/Soluciones para la Mejora de la Eficiencia y Seguridad del Páncreas Artificial mediante Arquitecturas de Control Multivariable Tolerantes a Fallos/
dc.type.version
info:eu-repo/semantics/publishedVersion
dc.identifier.doi
dc.identifier.idgrec
028334
dc.contributor.funder
dc.type.peerreviewed
peer-reviewed
dc.relation.FundingProgramme
dc.relation.ProjectAcronym
dc.identifier.eissn
1424-8220
DUGiDocs