Avaluació del tractament extern per reduir l’embrutiment biològic en membranes polimèriques submergides
dc.contributor.author
dc.contributor.other
dc.date.accessioned
2017-11-29T10:51:16Z
dc.date.available
2017-11-29T10:51:16Z
dc.date.issued
2017-09
dc.identifier.uri
dc.description.abstract
Water is a precious and necessary good for humans. We make great use of it be it for
industry or urban use. In consequence its quality is altered and generates what we
denominate waste waters. This water has to be treated to prevent negative impact on
the environment. To avoid this there are waste water treatments. Conventional
treatments in waste water treatment plants are composed of physic-chemical and
biological treatments. But those water treatment plants present limitations that
difficult improvement of the process.
This limitations can be balanced out by integrating other advanced technologies of
waste water treatment that will improve the treatment and generate better quality
water diminishing the impact on the environment. One of those systems is called
membrane bioreactor (MBR). This process generates much better water quality but
has two big inconvenient: the operational cost and the membrane fouling.
The membrane fouling is due to particle accumulation on the surface, negatively
affecting water filtration. Fouling is detected by the increase in trans-membrane (TMP)
pressure. In consequence there is an increment on the energetic cost and when
accumulated it can damage the membrane.
There exist different measures to help reduce fouling. Systems like the application of
airing to create turbulence and detach fouling. Also periodical back wash process to
release obstructed pores or chemical washes to recover filter capacity even though it
reduces the membrane useful life.
All these measures imply direct actions on the membranes. What we study is the
option to apply an external peptic treatment that coats the membrane surface, able to
prevent bio-fouling from membranes. With this treatment we could reduce back wash
frequency, airing flow or even chemical washes. Therefore we can reduce operational
costs from this technology increasing its profitability.
Comparison between treated membranes and non-treated ones indicates that we can
increase its permeability in low fluxes due to coating
dc.format.mimetype
application/pdf
dc.language.iso
cat
dc.relation.ispartofseries
Ciències Ambientals (TFG)
dc.rights
Attribution-NonCommercial-NoDerivs 3.0 Spain
dc.rights.uri
dc.subject
dc.title
Avaluació del tractament extern per reduir l’embrutiment biològic en membranes polimèriques submergides
dc.type
info:eu-repo/semantics/bachelorThesis
dc.rights.accessRights
info:eu-repo/semantics/openAccess