Automated localization of breast cancer in DCE-MRI
dc.contributor.author
dc.date.accessioned
2016-11-23T08:39:32Z
dc.date.available
2016-11-23T08:39:32Z
dc.date.issued
2015-02-01
dc.identifier.issn
1361-8415 (versió paper)
1361-8423 (versió electrònica)
dc.identifier.uri
dc.description.abstract
Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is increasingly being used for the detection and diagnosis of breast cancer. Compared to mammography, DCE-MRI provides higher sensitivity, however its specificity is variable. Moreover, DCE-MRI data analysis is time consuming and depends on reader expertise. The aim of this work is to propose a novel automated breast cancer localization system for DCE-MRI. Such a system can be used to support radiologists in DCE-MRI analysis by marking suspicious areas. The proposed method initially corrects for motion artifacts and segments the breast. Subsequently, blob and relative enhancement voxel features are used to locate lesion candidates. Finally, a malignancy score for each lesion candidate is obtained using region-based morphological and kinetic features computed on the segmented lesion candidate. We performed experiments to compare the use of different classifiers in the region classification stage and to study the effect of motion correction in the presented system. The performance of the algorithm was assessed using free-response operating characteristic (FROC) analysis. For this purpose, a dataset of 209 DCE-MRI studies was collected. It is composed of 95 DCE-MRI studies with 105 breast cancers (55 mass-like and 50 non-mass-like malignant lesions) and 114 DCE-MRI studies from women participating in a screening program which were diagnosed to be normal. At 4 false positives per normal case, 89% of the breast cancers (91% and 86% for mass-like and non-mass-like malignant lesions, respectively) were correctly detected
dc.description.sponsorship
The research leading to these results has received funding from the European Unions Seventh Framework Programme FP7 under Grant Agreement No. 306088. Albert Gubern-Mérida held a FPU Grant AP2009-2835
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier
dc.relation.isformatof
Reproducció digital del document publicat a: http://dx.doi.org/10.1016/j.media.2014.12.001
dc.relation.ispartof
© Medical Image Analysis, 2015, vol. 20, núm. 1, p. 265-274
dc.relation.ispartofseries
Articles publicats (D-ATC)
dc.rights
Tots els drets reservats
dc.subject
dc.title
Automated localization of breast cancer in DCE-MRI
dc.type
info:eu-repo/semantics/article
dc.rights.accessRights
info:eu-repo/semantics/embargoedAccess
dc.embargo.terms
Cap
dc.relation.projectID
info:eu-repo/grantAgreement/EC/FP7/306088
dc.type.version
info:eu-repo/semantics/publishedVersion
dc.identifier.doi
dc.identifier.idgrec
022525