Multi-channel registration of fractional anisotropy and T1-weighted images in the presence of atrophy: application to multiple sclerosis
dc.contributor.author
dc.date.accessioned
2016-11-17T07:41:25Z
dc.date.available
2016-11-17T07:41:25Z
dc.date.issued
2015
dc.identifier.issn
0393-5264
dc.identifier.uri
dc.description.abstract
Co-registration of structural T1-weighted (T1w) scans and diffusion tensor imaging (DTI)-derived fractional anisotropy (FA) maps to a common space is of particular interest in neuroimaging, as T1w scans can be used for brain segmentation while DTI can provide microstructural tissue information. While the effect of lesions on registration has been tackled and solutions are available, the issue of atrophy is still open to discussion. Multi-channel (MC) registration algorithms have the advantage of maintaining anatomical correspondence between different contrast images after registration to any target space. In this work, we test the performance of an MC registration approach applied to T1w and FA data using simulated brain atrophy images. Experimental results are compared with a standard single-channel registration approach.
Multi-channel registration of fractional anisotropy and T1-weighted images in the presence of atrophy: application to multiple sclerosis Both qualitative and quantitative evaluations are presented, showing that the MC approach provides better alignment with the target while maintaining better T1w and FA co-alignment
dc.description.sponsorship
This work has also been partially supported by “La Fundació la Marató de TV3” and by Retos de Investigación TIN2014-55710-R
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
CIC Edizioni internazionali
dc.relation
info:eu-repo/grantAgreement/MINECO//TIN2014-55710-R/ES/HERRAMIENTAS DE NEUROIMAGEN PARA MEJORAR EL DIAGNOSIS Y EL SEGUIMIENTO CLINICO DE LOS PACIENTES CON ESCLEROSIS MULTIPLE/
dc.relation.isformatof
Reproducció digital del document publicat a: http://dx.doi.org/10.11138/FNeur/2015.30.4.245
dc.relation.ispartof
© Functional Neurology, 2015, vol. 30, núm. 4, p. 245-256
dc.relation.ispartofseries
Articles publicats (D-ATC)
dc.rights
Tots els drets reservats
dc.subject
dc.title
Multi-channel registration of fractional anisotropy and T1-weighted images in the presence of atrophy: application to multiple sclerosis
dc.type
info:eu-repo/semantics/article
dc.rights.accessRights
info:eu-repo/semantics/openAccess
dc.embargo.terms
Cap
dc.type.version
info:eu-repo/semantics/publishedVersion
dc.identifier.doi
dc.identifier.idgrec
025451
dc.contributor.funder
dc.relation.ProjectAcronym
dc.identifier.eissn
1971-3274