Reliability of the ABC/2 Method in Determining Acute Infarct Volume
dc.contributor.author
dc.date.accessioned
2015-12-09T10:33:00Z
dc.date.available
2015-12-09T10:33:00Z
dc.date.issued
2012
dc.identifier.issn
1051-2284
1051-2284
dc.identifier.uri
dc.description.abstract
Background and Purpose: Infarct volume is used as a surrogate outcome measure in clinical trials of therapies for acute ischemic stroke. ABC/2 is a fast volumetric method, but its accuracy remains to be determined. We aimed to study the accuracy and reproducibility of ABC/2 in determining acute infarct volume with diffusion-weighted imaging. Methods: We studied 86 consecutive patients with acute ischemic stroke. Three blinded observers determined volume with the ABC/2 method, and the results were compared with those of the manual planimetric method. Results: The ABC/2 technique overestimated infarct volume by a median false increase (variable ABC/2 volume minus planimetric volume) of 7.33 cm 3 (1.29, 22.170, representing a 162.56% increase over the value of the gold standard (variable ABC/2 volume over planimetric volume) (121.70, 248.52). In each method, the interrater reliability was excellent: the intraclass correlations were .992 and .985 for the ABC/2 technique and planimetric method, respectively. Conclusions: ABC/2 is volumetric method with clinical value but it consistently overestimates the real infarct volume
dc.description.sponsorship
This work was supported in part by governments' grants: From MEC TIN2010-21089-C03-01 and from Fondo de Investigaciones Sanitarias (FIS) grant (reference PI09/00596)
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
Wiley
dc.relation
info:eu-repo/grantAgreement/MICINN//TIN2010-21089-C03-01/ES/CONTENIDO DIGITAL PARA JUEGOS SERIOS: CREACION, GESTION, RENDERIZADO E INTERACCION/
dc.relation.isformatof
Reproducció digital del document publicat a: http://dx.doi.org/10.1111/j.1552-6569.2011.00588.x
dc.relation.ispartof
© Journal of Neuroimaging, 2012, vol. 22, núm. 2, p. 155-159
dc.relation.ispartofseries
Articles publicats (D-IMA)
dc.rights
Tots els drets reservats
dc.title
Reliability of the ABC/2 Method in Determining Acute Infarct Volume
dc.type
info:eu-repo/semantics/article
dc.rights.accessRights
info:eu-repo/semantics/embargoedAccess
dc.embargo.terms
Cap
dc.date.embargoEndDate
info:eu-repo/date/embargoEnd/2026-01-01
dc.type.version
info:eu-repo/semantics/publishedVersion
dc.identifier.doi
dc.identifier.idgrec
013123
dc.contributor.funder
dc.relation.ProjectAcronym
dc.identifier.eissn
1552-6569