Two polydimethylsiloxane rod extraction methods for the sensitive determination of phenolic compounds in water samples
dc.contributor.author
dc.date.accessioned
2015-11-17T15:13:24Z
dc.date.available
2015-11-17T15:13:24Z
dc.date.issued
2014
dc.identifier.issn
1615-9306
dc.identifier.uri
dc.description.abstract
Simple, precise, and low-cost methods for the simultaneous determination of phenolic endocrine disrupting compounds such as bisphenol A, trichlorophenol, pentachlorophenol, 4-nonylphenol, and 4-octylphenol in water samples were developed. The Direct, in situ derivatization methods are based on polydimethylsiloxane rod extraction followed by liquid desorption and chromatographic analysis by liquid chromatography and diode array detection. Several parameters affecting the extraction and desorption of the phenolic compounds and their acetylated derivates were studied, as well as the chromatographic and detection conditions. For the direct method, determination coefficients (r<sup>2</sup>) > 0.990 and LODs in the 0.6-2 μg/L range were obtained for all compounds except bisphenol A (9.5 μg/L). With the derivatization-based method, based on in situ acetylation, lower limits of detection (0.3-0.9 μg/L) were obtained for all the compounds with r<sup>2</sup> > 0.988 and RSDs in the 2-9% range. The developed methods were applied to the analysis of spiked water samples obtaining recoveries of between 60.2 and 131.7% for the direct method, and of between 76.6 and 108.2% for the derivatization-based method. The results demonstrate the feasibility of using these twomethods for determining bisphenol A, trichlorophenol, pentachlorophenol, 4-nonylphenol, and 4-octylphenol in water
dc.description.sponsorship
This study has been financed by the Spanish Ministry of Science and Innovation through projects CTM2011-28765-C02-02 and CGL2010-22168-C03-03, and an FPI grant (Ref. BES-2009-024892) awarded to C. Valls-Cantenys
dc.format.mimetype
application/pdf
dc.language.iso
eng
dc.publisher
Wiley-VCH Verlag
dc.relation
info:eu-repo/grantAgreement/MICINN//CTM2011-28765-C02-02/ES/COMPORTAMIENTO Y ELIMINACION DE CONTAMINANTES ORGANICOS EMERGENTES EN SISTEMAS DE TRATAMIENTOS DE AGUAS. EVALUACION DE SISTEMAS TERCIARIOS./
info:eu-repo/grantAgreement/MICINN//CGL2010-22168-C03-02/ES/APLICACION DE AGUA NO CONVENCIONAL (TRATADA-DESALADA) Y FANGOS PROCEDENTES DE DEPURADORAS URBANAS Y SU IMPACTO EN EL MEDIO ACUIFERO Y SUELOS. ETUDIOS DE CAMPOY LABORATORIO/
dc.relation.isformatof
Reproducció digital del document publicat a: http://dx.doi.org/10.1002/jssc.201400823
dc.relation.ispartof
© Journal of Separation Science, 2014, vol. 37, núm. 24, p. 3706-3713
dc.relation.ispartofseries
Articles publicats (D-Q)
dc.rights
Tots els drets reservats
dc.subject
dc.title
Two polydimethylsiloxane rod extraction methods for the sensitive determination of phenolic compounds in water samples
dc.type
info:eu-repo/semantics/article
dc.rights.accessRights
info:eu-repo/semantics/embargoedAccess
dc.embargo.terms
Cap
dc.date.embargoEndDate
info:eu-repo/date/embargoEnd/2026-01-01
dc.type.version
info:eu-repo/semantics/publishedVersion
dc.identifier.doi
dc.identifier.idgrec
023357
dc.contributor.funder
dc.relation.ProjectAcronym
dc.identifier.eissn
1615-9314