Tesis doctorals (VICOROB) http://hdl.handle.net/10256/11654 Thu, 22 Jan 2026 17:22:35 GMT 2026-01-22T17:22:35Z Graph-based underwater localization techniques considering a rigorous on Lie group formulation http://hdl.handle.net/10256/27704 Graph-based underwater localization techniques considering a rigorous on Lie group formulation Vial Serrat, Pau ENG- The main contributions of this thesis are two, properly presented in the four articles that form the articles compendium. The first one is the development of a scan matching algorithm based on Gaussian Mixture Models (GMMs) to represent the sensor noise projected to the scan that returns the uncertainty associated with the alignment result, an essential metric in SLAM problems. In addition, the Bayesian-GMM algorithm is first introduced to learn a GMM from a point cloud. The second main contribution of this thesis is the development of an algorithm to jointly preintegrate Inertial Measurement Unit (IMU) and Doppler Velocity Log (DVL) measurements to reach a tightly coupled estimation in an underwater Graph SLAM problem. Moreover, it allows compensating the preintegrated measurement from the Earth rotation rate measured by high grade IMUs. Both algorithms are formulated considering Lie algebra to properly manipulate robot states and sensor measurements, introducing the SEN (3) group to jointly preintegrate IMU and DVL measurements. Finally, this thesis also includes field experiments that prove the performance of the two proposed underwater navigators, one applying a Mechanical Profiling Sonar (MPS) and the other using a Mechanical Scanning MultiBeam EchoSounder (MS-MBES). The software architecture developed to implement both navigators is also presented, which provides a graph-based navigation framework to implement other navigators applying other sensor modalities; CAT- Les contribucions principals d’aquesta tesi són dues, degudament presentades en els quatre articles que conformen el compendi d’articles. La primera és el desenvolupament d’un algorisme de registre de vistes basat en Models de Barreja de Gaussianes (GMMs) per representar el soroll del sensor projectat a la vista i que retorna la incertesa associada al resultat d’alineament, una mètrica indispensable en problemes de SLAM. A més, s’introdueix per primera vegada l’algorisme GMM-Bayesià per aprendre un GMM a partir d’un núvol de punts. La segona gran contribució de la tesi és el desenvolupament d’un algorisme per preintegrar de manera conjunta les mesures d’una Unitat de Mesura Inercial (IMU) i d’un Registre de Velocitat de Doppler (DVL) per assolir una estimació estretament acoblada en un problema de Graf SLAM submarí. A més, l’algorisme permet compensar la mesura preintegrada de la velocitat de rotació de la Terra mesurada per IMUs d’alta precisió. Ambdós algorismes estan formulats considerant l’àlgebra de Lie per manipular de manera adequada els estats del robot i les mesures dels sensors, introduint el grup SEN(3) per preintegrar de manera conjunta les mesures de la IMU i del DVL. Finalment, aquesta tesi també inclou experiments de camp que proven les prestacions dels dos navegadors submarins proposats, un aplicant un Sonar Perfilador Mecànic (MPS) i l’altre usant una EcoSonda MultiFeix d’Esconeig Mecànic (MS-MBES). L’arquitectura de software desenvolupada per implementar ambdós navegadors també es presenta, la qual proporciona un entorn de programació de navegació basada en grafs per implementar altres navegadors aplicant altres modalitats sensorials Fri, 19 Sep 2025 00:00:00 GMT http://hdl.handle.net/10256/27704 2025-09-19T00:00:00Z Applications of deep learning techniques in magnetic resonance imaging for multiple sclerosis: from research innovations to clinical implementation http://hdl.handle.net/10256/26725 Applications of deep learning techniques in magnetic resonance imaging for multiple sclerosis: from research innovations to clinical implementation Valencia Rodriguez, Liliana ENG - This thesis explores how advanced artificial intelligence techniques, specifically deep learning, can improve the analysis of brain scans (MRI) for people with multiple sclerosis (MS). The study focuses on three key areas. First, it introduces a new AI tool designed to accurately and consistently isolate the brain from the surrounding tissues in MRI scans. This is crucial for many analyses and can improve the accuracy of brain volume measurements, which are important for tracking disease progression. Secondly, the research develops a method to generate synthetic brain scans from existing ones. This can help improve the detection of MS lesions (areas of brain damage) while potentially reducing the need for expensive and time-consuming MRI scans. Finally, the study investigates the practical challenges of bringing these AI tools into real-world clinical use. This includes navigating regulations and ensuring the safety and effectiveness of these technologies for patients. In summary, this research aims to improve the diagnosis and management of MS by developing and implementing innovative AI solutions for analyzing brain MRI scans; CAT - Aquesta tesi explora com les tècniques avançades d'intel·ligència artificial, concretament l'aprenentatge profund, poden millorar l'anàlisi de les exploracions cerebrals (MRI) per a persones amb esclerosi múltiple (EM). L'estudi se centra en tres àrees clau. En primer lloc, introdueix una nova eina d'IA dissenyada per aïllar de manera precisa i coherent el cervell dels teixits circumdants en les exploracions de ressonància magnètica. Això és crucial per a moltes anàlisis i pot millorar la precisió de les mesures del volum cerebral, que són importants per fer un seguiment de la progressió de la malaltia. En segon lloc, la investigació desenvolupa un mètode per generar exploracions cerebrals sintètiques a partir de les existents. Això pot ajudar a millorar la detecció de lesions d'EM (àrees de dany cerebral) alhora que redueix potencialment la necessitat d'exploracions de ressonància magnètica costoses i que requereixen temps. Finalment, l'estudi investiga els reptes pràctics de portar aquestes eines d'IA a l'ús clínic del món real. Això inclou navegar per les normatives i garantir la seguretat i l'eficàcia d'aquestes tecnologies per als pacients. En resum, aquesta investigació pretén millorar el diagnòstic i la gestió de l'EM desenvolupant i implementant solucions innovadores d'IA per analitzar ressonàncies magnètiques cerebrals Thu, 06 Mar 2025 00:00:00 GMT http://hdl.handle.net/10256/26725 2025-03-06T00:00:00Z Deep learning methods for extraction of neuroimage markers in the prognosis of brain pathologies http://hdl.handle.net/10256/23047 Deep learning methods for extraction of neuroimage markers in the prognosis of brain pathologies Clèrigues Garcia, Albert This PhD thesis focuses on improving the extraction of neuroimage markers for the prognosis and outcome prediction of neurological pathologies such as ischemic stroke, Alzheimer’s disease (AD) and multiple sclerosis (MS). Our work has been developed on two of the most relevant neuroimage markers for diagnosis and prediction, brain lesion segmentation and longitudinal atrophy quantification. Brain lesion segmentation can be directly used in MS and ischemic stroke as a prognostic marker and can also be useful for other downstream segmentation tasks. In MS, disease activity produces very characteristic lesions which can help with diagnosis and prognosis of the pathology. In ischemic stroke, lesion segmentation can inform the treatment decision workflow by quantifying the amount of tissue that could be salvaged against the risks of surgical intervention. We also tackle in this PhD thesis the task of brain tissue segmentation for longitudinal atrophy quantification, a validated prognostic image marker in MS and AD. Measurements of longitudinal atrophy can be used to assess the rate of disease progression and might even help to predict AD onset years in advance. In MS patients, an accelerated rate of brain atrophy is also observed as a result of disease activity and is used as a prognostic marker and to evaluate the response of disease-modifying treatments; Aquesta tesi doctoral se centra en millorar l’extracció de marcadors de neuroimatge per al pronòstic i predicció de l’estat del pacient en patologies neurològiques com l’ictus isquèmic, la malaltia d’Alzheimer o l’esclerosi múltiple (EM). El nostre treball ha estat desenvolupat en dos dels marcadors de neuroimatge més rellevants per al diagnòstic i la predicció; la segmentació de lesions cerebrals i la quantificació longitudinal d’atròfia. La segmentació de lesions pot ser utilitzada directament en ictus i en EM com a marcador del pronòstic i també pot ser útil en posteriors tasques de segmentació. A l’EM, l’activitat de la malaltia produeix lesions molt característiques que poden informar el diagnòstic i el pronòstic de la patologia. A l’ictus isquèmic, la segmentació de la lesió pot assistir en la decisió del tractament mitjançant la quantificació del teixit que podria salvar-se front als riscos de la intervenció quirúrgica. També abordem en aquesta tesi doctoral la segmentació del teixit cerebral per a la quantificació de l’atròfia longitudinal, un marcador d’imatge pronòstic validat a la EM i la malaltia d’Alzheimer. Les mesures de l’atròfia longitudinal es poden fer servir per avaluar la velocitat de progressió de la malaltia i fins i tot podrien ajudar a predir l’inici de la malaltia d’Alzheimer anys abans de mostrar els primers símptomes. En pacients amb EM, també s’observa una taxa accelerada d’atròfia cerebral com a resultat de l’activitat de la malaltia i la seva mesura pot servir com a marcador pronòstic i també per avaluar la resposta als tractaments modificadors de la malaltia Mon, 13 Feb 2023 00:00:00 GMT http://hdl.handle.net/10256/23047 2023-02-13T00:00:00Z Underwater 3d sensing using structured light: development of an underwater laser scanner and a non-rigid point cloud registration method http://hdl.handle.net/10256/23029 Underwater 3d sensing using structured light: development of an underwater laser scanner and a non-rigid point cloud registration method Castillón Sánchez, Miguel Accurate underwater 3D perception is essential to advance towards the automation of expensive, dangerous and/or time-consuming tasks, such as the inspection, maintenance and repair of off-shore industrial sites. Accurate underwater 3D sensors can potentially have a large positive impact on the progress of tasks like object detection and semantic mapping, which are key to the development of robotic platforms capable of a higher level of abstraction. Moreover, these advances would decidedly contribute to the transition from remotely operated vehicles (ROVs) towards autonomous underwater vehicles (AUVs) in industrial operations. However, accurate underwater 3D perception is very hard to achieve because of the many physical particularities of light propagation in water, including refraction: the direction of light rays changes due to the different refraction indices of the media it travels through. This thesis focuses on the development of a novel underwater 3D scanner and a nonrigid point cloud registration method aimed at enabling underwater 3D reconstructions with accuracies in the order of millimeters both in static and dynamic missions. The thesis is structured according to these two main contributions, which resulted in five journal articles. The first main contribution of this thesis is designing and building an underwater 3D scanner using a 2-axis mirror. The second axis of the rotating mirror allows us to project optimally-curved scanning patterns designed to counteract refraction, so that they transform into straight lines when entering the water. This results in a decrease in computational complexity of the 3D reconstruction while maintaining millimeter accuracy. Minor contributions of this part of the thesis are the design of a ray-tracing model to study the effect of each optical component on the quality of the 3D reconstruction and the development of a simplified calibration algorithm based on numeric projection functions. The second main contribution of this thesis is the development of a non-rigid point cloud registration method that can successfully minimize the motion distortion that appears when the scanner is mounted on a moving robot. Finally, this thesis also includes unpublished 3D reconstructions performed during missions both in the water tank at the Centre d’Investigació en Robòtica Submarina (CIRS) and at sea; Una percepció submarina 3D d’alta precisió és essencial per avançar cap a l’automatització de tasques com la inspecció, el manteniment i la reparació d’estructures industrials submarines, las quals actualment comporten un elevat preu, risc i/o durada. Disposar de sensors 3D subaquàtics d’alta precisió podria accelerar el progrés de tasques com la detecció d’objectes i el mapejat semàntic, claus per al desenvolupament de plataformes robòtiques capaces d’un nivell d’abstracció més alt. A més, aquest avenç contribuiria de forma decisiva a la transició a nivell industrial des de vehicles submarins operats remotament (ROVs) cap a vehicles submarins autònoms (AUVs). No obstant això, aconseguir percepció 3D d’alta precisió sota l’aigua és difícil per les moltes particularitats físiques de la propagació de la llum a l’aigua, incloent-hi la refracció: la llum canvia de direcció a causa dels diferents índexs de refracció dels mitjans pels quals viatja. Aquesta tesi se centra en el desenvolupament d’un nou escàner 3D submarí i un mètode de registre no-rígid de núvols de punts amb l’objectiu de crear reconstruccions submarines en 3D amb precisions a l’ordre de mil·límetres tant en missions estàtiques com dinàmiques. La tesi s’estructura segons aquestes dues contribucions principals, las quals ens han permès publicar cinc articles en revistes científiques. La primera contribució principal és el disseny i la construcció d’un escàner 3D submarí usant un mirall de dos eixos de rotació. El segon eix del mirall ens permet projectar patrons d’escaneig corbats de manera òptima per contrarestar la refracció, de manera que es transformin en línies rectes en entrar a l’aigua. Així, podem disminuir la complexitat computacional de la reconstrucció 3D mentre mantenim una precisió mil·limètrica. Altres contribucions de menor rang d’aquesta part de la tesi són el disseny d’un model de la direcció del feix làser per estudiar l’efecte de cada component òptic en la qualitat de la reconstrucció 3D, i el desenvolupament d’un algoritme de calibració simplificat basat en funcions numèriques de projecció. La segona contribució principal és un mètode de registre no-rígid de núvols de punts que minimitza la distorsió present als escanejats quan el sensor està muntat en un robot en moviment. Finalment, aquesta tesi també inclou reconstruccions 3D no publicades fins ara i que van ser realitzades en missions tant a la piscina del Centre d’Investigació en Robòtica Submarina (CIRS) com al mar Fri, 10 Feb 2023 00:00:00 GMT http://hdl.handle.net/10256/23029 2023-02-10T00:00:00Z