Identification of intra-patient variability in the postprandial response of patients with type 1 diabetes

Text Complet
Identification-intra-patient.pdf embargoed access
Sol·licita còpia a l'autor de l'article
En omplir aquest formulari esteu demanant una còpia de l'article dipositat al repositori institucional (DUGiDocs) al seu autor o a l'autor principal de l'article. Serà el mateix autor qui decideixi lliurar una còpia del document a qui ho sol•liciti si ho creu convenient. En tot cas, la Biblioteca de la UdG no intervé en aquest procés ja que no està autoritzada a facilitar articles quan aquests són d'accés restringit.
Compartir
Identification of individualized models for patients with type 1 diabetes is of vital importance for the development of a successful artificial pancreas and other model-based strategies of insulin treatment. However, the huge intra-patient glycemic variability frequently prevents the identification of reliable models, especially in the postprandial period. In this work, the identification of postprandial models characterizing intra-patient variability is addressed. Methods: Regarding the postprandial response, uncertainties due to physiological variability, input errors in insulin infusion rate and in meal content estimation are characterized by means of interval models, which predict a glucose envelope containing all possible patient responses according to the model. Multi-objective optimization is performed over a cohort of virtual patients, minimizing both the fitting error and the output glucose envelope width. A Pareto Front is then built ranging from classic identification representing average behaviors to interval identification guaranteeing full enclosure of the measurements. A method for the selection of the best individual in the Pareto Front for identification from home monitoring data with a continuous glucose monitor is presented, reducing the overestimation of patient's variability due to monitor inaccuracies and noise. Results: Identification using glucose reference data provide model bands that accurately fit all data points in the used virtual data set. Identification from continuous glucose monitor data, using two different width estimation procedures yield very similar prediction capabilities of around 60% of the data points predicted, and less than a 5% average error. Conclusions: In this work, a new approach to evaluate intra-patient variability in the identification of postprandial models is presented. The proposed method is feasible and shows good prediction capabilities in a 5-h time horizon as compared to reference measurements ​
​Tots els drets reservats